Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38.182
Filtrar
1.
PLoS One ; 19(4): e0302293, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640122

RESUMO

Smoking is a worldwide epidemic and increased prices are one of the most cost-effective measures to reduce tobacco consumption. This article aims to estimate the price and income elasticity of cigarettes for different population groups in Ecuador. The National Survey of Urban and Rural Household Income and Expenditures (ENIGHUR) 2011-2012 was used, which has information on household cigarette consumption and its sociodemographic characteristics. Deaton's Almost Ideal Demand System, which decouples the effect of quality on the price of the good, was applied. The elasticities were calculated for several groups: urban/rural, income levels (tertiles), education level, sex and age ranges of the household head, and frequency of cigarette purchases in households. The estimated price elasticity nationwide is -0.89 and the income elasticity is 0.41, both statistically significant. Households headed by women (-2.22) are more sensitive to an increase in cigarette prices than those headed by men (-0.65) and households headed by people between 20 and 40 years of age (-2.32) have a higher price elasticity compared to country-level estimations. Differences within other groups are not statistically significant.


Assuntos
Impostos , Produtos do Tabaco , Masculino , Humanos , Feminino , Equador/epidemiologia , Comércio , Fatores Socioeconômicos , Elasticidade
2.
J Mech Behav Biomed Mater ; 154: 106532, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38574437

RESUMO

Polymeric lattice materials with micro/nano-structures are attractive for applications in a wide range of bioengineering systems. Resent experimental results show that elastic constitutive law of polymer materials is in line with the Cosserat elasticity. In this work, a Cosserat continuum spectral element method is employed to explore the size-dependent mechanical performance of polymer polymeric lattice with horseshoe microstructures, efficiently. The mechanical performance predicted by the proposed method agrees very well with the experiment data. Our results demonstrate that size effects are significant in polymeric lattice materials. The size-dependent negative Poisson's ratio is found in the polymeric lattice materials with the same topological structure due to the size effect caused by the Cosserat elasticity of the polymer materials. It could be implied that it is possible to continuously adjust the negative Poisson's ratio of the polymeric lattice material over a wide range by only changing its microstructural size.


Assuntos
Polímeros , Elasticidade
3.
PLoS One ; 19(4): e0301560, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635736

RESUMO

The new material introduced by the ITTF in 2014 for table tennis balls has attracted significant attention from players and coaches. Changes in both material selection and production procedures are likely to have affected the static performance of the ball. However, the raw data regarding the elasticity and hardness of these new material balls, encompassing various brands and structures, often lacks practical information crucial for players' rapid adaptation and daily training. The static properties tested in this study were provided by the ITTF, covering both hardness and elasticity. Based on computed variables, this study revealed that the hardness of seam balls at the equator was not consistently higher than that at the pole. Additionally, the study confirmed that the hardness and bounce height of new material balls exceeded those of celluloid. Furthermore, correlation analysis was conducted to examine the relationship between these two properties, revealing a significant correlation between the hardness of seamless balls and their elasticity. This study provides an analysis of the static performance of various types of new material balls, aiding players and coaches in better understanding official event balls and offering a theoretical foundation for the formulation of diverse training and game strategies.


Assuntos
Tênis , Dureza , Elasticidade
4.
Int J Colorectal Dis ; 39(1): 56, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662090

RESUMO

PURPOSE: This study aimed to clarify the relationship between changes in elasticity and anorectal function before and after chemoradiotherapy. METHODS: This is a single-center prospective cohort study (Department of Surgical Oncology, The University of Tokyo). We established a technique to quantify internal anal sphincter hardness as elasticity using transanal ultrasonography with real-time tissue elastography. Twenty-seven patients with post-chemoradiotherapy rectal cancer during 2019-2022 were included. Real-time tissue elastography with transanal ultrasonography was performed before and after chemoradiotherapy to measure internal anal sphincter hardness as "elasticity" (hardest (0) to softest (255); decreased elasticity indicated sclerotic changes). The relationship between the increase or decrease in elasticity pre- and post-chemoradiotherapy and the maximum resting pressure, maximum squeeze pressure, and Wexner score were the outcome measures. RESULTS: A decrease in elasticity was observed in 16/27 (59.3%) patients after chemoradiotherapy. Patients with and without elasticity decrease after chemoradiotherapy comprised the internal anal sphincter sclerosis and non-sclerosis groups, respectively. The maximum resting pressure post-chemoradiotherapy was significantly high in the internal anal sphincter sclerosis group (63.0 mmHg vs. 47.0 mmHg), and a majority had a worsening Wexner score (60.0% vs. 18.2%) compared with that of the non-sclerosis group. Decreasing elasticity (internal anal sphincter sclerosis) correlated with a higher maximum resting pressure (r = 0.36); no correlation was observed between the degree of elasticity change and maximum squeeze pressure. CONCLUSION: Internal anal sphincter sclerosis due to chemoradiotherapy may correlate to anorectal dysfunction.


Assuntos
Canal Anal , Quimiorradioterapia , Técnicas de Imagem por Elasticidade , Neoplasias Retais , Humanos , Canal Anal/diagnóstico por imagem , Canal Anal/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Quimiorradioterapia/efeitos adversos , Idoso , Neoplasias Retais/terapia , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/fisiopatologia , Reto/fisiopatologia , Reto/diagnóstico por imagem , Elasticidade , Estudos Prospectivos , Adulto , Cuidados Pré-Operatórios , Pressão
5.
J Colloid Interface Sci ; 666: 529-539, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38613975

RESUMO

Elastic carbon aerogels have promising applications in the field of wearable sensors. Herein, a new strategy for preparing carbon aerogels with excellent compressive strength and strain, shape recovery, and fatigue resistance was proposed based on the structure design and carbonization optimization of nanocellulose-based precursor aerogels. By the combination of directional freezing and zinc ion cross-linking, bacterial cellulose (BC)/alginate (SA) composite aerogels with high elasticity and compressive strength were first achieved. The existance of zinc ions also significantly improved the carbon retention rate and inhibited structural shrinkage, thus making the carbon aerogels retain ultra-high elasticity and fatigue resistance after compression. Moreover, the carbon aerogel possessed excellent piezoresistive pressure sensing performance with a wide detection range of 0-7.8 kPa, high sensitivity of 11.04 kpa-1, low detection limit (2 % strain), fast response (112 ms), and good durability (over 1,000 cycles). Based on these excellent properties, the carbon aerogel pressure sensors were further successfully used for human motion monitoring, from joint motion to and speech recognition.


Assuntos
Alginatos , Carbono , Celulose , Elasticidade , Géis , Dispositivos Eletrônicos Vestíveis , Carbono/química , Géis/química , Humanos , Celulose/química , Alginatos/química , Anisotropia , Tamanho da Partícula , Propriedades de Superfície , Zinco/química
6.
Commun Biol ; 7(1): 451, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622287

RESUMO

This report presents an optical fibre-based endo-microscopic imaging tool that simultaneously measures the topographic profile and 3D viscoelastic properties of biological specimens through the phenomenon of time-resolved Brillouin scattering. This uses the intrinsic viscoelasticity of the specimen as a contrast mechanism without fluorescent tags or photoacoustic contrast mechanisms. We demonstrate 2 µm lateral resolution and 320 nm axial resolution for the 3D imaging of biological cells and Caenorhabditis elegans larvae. This has enabled the first ever 3D stiffness imaging and characterisation of the C. elegans larva cuticle in-situ. A label-free, subcellular resolution, and endoscopic compatible technique that reveals structural biologically-relevant material properties of tissue could pave the way toward in-vivo elasticity-based diagnostics down to the single cell level.


Assuntos
Imageamento Tridimensional , Microscopia , Animais , Microscopia/métodos , Imageamento Tridimensional/métodos , Caenorhabditis elegans , Elasticidade , Biologia
7.
BMC Public Health ; 24(1): 1020, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609956

RESUMO

BACKGROUND: Consumption of sugar-sweetened beverages (SSB) is a major global public health problem. Increasing the price of SSBs through taxation is an effective tool to reduce SSB consumption. Price-elasticity estimates are useful in measuring the effect of taxation on consumption. We estimated the own price elasticities of demand for SSBs in Bangladesh, which will inform how SSB taxes could affect behaviour. METHODS: We used Household Income and Expenditure Survey (HIES) 2016 data, which is a nationally representative dataset at the household level across the country and is conducted using stratified random sampling method. Deaton's method was used to estimate the price elasticities for SSBs in Bangladesh. RESULTS: We found that the own price elasticity for SSBs varied between - 0.53% to -1.17% by types of SSBs in Bangladesh. The price elasticity for soft drinks was - 1.17, indicating that if the price of soft drinks increases by 10% via taxes, the quantity consumed of these beverages would reduce by 11.7%. CONCLUSION: This is the first study that estimates the own price elasticities of demand for SSBs in Bangladesh. Our results suggest to raise SSB prices through increased taxation in order to reduce SSB consumption and ensure public health gains in Bangladesh.


Assuntos
Bebidas Adoçadas com Açúcar , Humanos , Bangladesh , Bebidas , Impostos , Elasticidade
8.
Soft Matter ; 20(16): 3483-3498, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38587658

RESUMO

A breast-cancer tumor develops within a stroma, a tissue where a complex extracellular matrix surrounds cells, mediating the cancer progression through biomechanical and -chemical cues. Current materials partially mimic the stromal matrix in 3D cell cultures but methods for measuring the mechanical properties of the matrix at cell-relevant-length scales and stromal-stiffness levels are lacking. Here, to address this gap, we developed a characterization approach that employs probe-based microrheometry and Bayesian modeling to quantify length-scale-dependent mechanics and mechanical heterogeneity as in the stromal matrix. We examined the interpenetrating network (IPN) composed of alginate scaffolds (for adjusting mechanics) and type-1 collagen (a stromal-matrix constituent). We analyzed viscoelasticity: absolute-shear moduli (stiffness/elasticity) and phase angles (viscous and elastic characteristics). We determined the relationship between microrheometry and rheometry information. Microrheometry reveals lower stiffness at cell-relevant scales, compared to macroscale rheometry, with dependency on the length scale (10 to 100 µm). These data show increasing IPN stiffness with crosslinking until saturation (≃15 mM of Ca2+). Furthermore, we report that IPN stiffness can be adjusted by modulating collagen concentration and interconnectivity (by polymerization temperature). The IPNs are heterogeneous structurally (in SEM) and mechanically. Interestingly, increased alginate crosslinking changes IPN heterogeneity in stiffness but not in phase angle, until the saturation. In contrast, such changes are undetectable in alginate scaffolds. Our nonlinear viscoelasticity analysis at tumor-cell-exerted strains shows that only the softer IPNs stiffen with strain, like the stromal-collagen constituent. In summary, our approach can quantify the stromal-matrix-related viscoelasticity and is likely applicable to other materials in 3D culture.


Assuntos
Alginatos , Matriz Extracelular , Matriz Extracelular/química , Matriz Extracelular/metabolismo , Humanos , Alginatos/química , Técnicas de Cultura de Células em Três Dimensões , Viscosidade , Células Estromais/citologia , Células Estromais/metabolismo , Elasticidade , Tecidos Suporte/química , Colágeno Tipo I/química , Colágeno Tipo I/metabolismo , Fenômenos Biomecânicos , Reologia , Modelos Biológicos , Teorema de Bayes
9.
J Biomech Eng ; 146(9)2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38581377

RESUMO

The continuous softening behavior of the brain tissue, i.e., the softening in the primary loading path with an increase in deformation, is modeled in this work as a state of hyperelasticity up to the onset of failure. That is, the softening behavior is captured via a core hyperelastic model without the addition of damage variables and/or functions. Examples of the application of the model will be provided to extant datasets of uniaxial tension and simple shear deformations, demonstrating the capability of the model to capture the whole-range deformation of the brain tissue specimens, including their softening behavior. Quantitative and qualitative comparisons with other models within the brain biomechanics literature will also be presented, showing the clear advantages of the current approach. The application of the model is then extended to capturing the rate-dependent softening behavior of the tissue by allowing the parameters of the core hyperelastic model to evolve, i.e., vary, with the deformation rate. It is shown that the model captures the rate-dependent and softening behaviors of the specimens favorably and also predicts the behavior at other rates. These results offer a clear set of advantages in favor of the considered modeling approach here for capturing the quasi-static and rate-dependent mechanical properties of the brain tissue, including its softening behavior, over the existing models in the literature, which at best may purport to capture only a reduced set of the foregoing behaviors, and with ill-posed effects.


Assuntos
Encéfalo , Elasticidade , Encéfalo/fisiologia , Fenômenos Biomecânicos , Modelos Biológicos , Estresse Mecânico , Humanos
10.
J Chem Phys ; 160(14)2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38591677

RESUMO

Coarse-grained models have emerged as valuable tools to simulate long DNA molecules while maintaining computational efficiency. These models aim at preserving interactions among coarse-grained variables in a manner that mirrors the underlying atomistic description. We explore here a method for testing coarse-grained vs all-atom models using stiffness matrices in Fourier space (q-stiffnesses), which are particularly suited to probe DNA elasticity at different length scales. We focus on a class of coarse-grained rigid base DNA models known as cgDNA and its most recent version, cgDNA+. Our analysis shows that while cgDNA+ closely follows the q-stiffnesses of the all-atom model, the original cgDNA shows some deviations for twist and bending variables, which are rather strong in the q → 0 (long length scale) limit. The consequence is that while both cgDNA and cgDNA+ give a suitable description of local elastic behavior, the former misses some effects that manifest themselves at longer length scales. In particular, cgDNA performs poorly on twist stiffness, with a value much lower than expected for long DNA molecules. Conversely, the all-atom and cgDNA+ twist are strongly length scale dependent: DNA is torsionally soft at a few base pair distances but becomes more rigid at distances of a few dozen base pairs. Our analysis shows that the bending persistence length in all-atom and cgDNA+ is somewhat overestimated.


Assuntos
DNA , Elasticidade , Pareamento de Bases
11.
Sci Rep ; 14(1): 8160, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589521

RESUMO

To analyze the changing trend of CH and CRF values under different influencing factors in T2DM patients. A total of 650 patients with T2DM were included. We discovered that the course of T2DM, smoking history, BMI, and FBG, DR, HbA1c, TC, TG, and LDL-C levels were common risk factors for T2DM, while HDL-C levels were a protective factor. Analyzing the CH and CRF values according to the course of diabetes, we discovered that as T2DM continued to persist, the values of CH and CRF gradually decreased. Moreover, with the increase in FBG levels and the accumulation of HbA1c, the values of CH and CRF gradually decreased. In addition, in patients with HbA1c (%) > 12, the values of CH and CRF decreased the most, falling by 1.85 ± 0.33 mmHg and 1.28 ± 0.69 mmHg, respectively. Compared with the non-DR group, the CH and CRF values gradually decreased in the mild-NPDR, moderate-NPDR, severe-NPDR and PDR groups, with the lowest CH and CRF values in the PDR group. In patients with T2DM, early measurement of corneal biomechanical properties to evaluate the change trend of CH and CRF values in different situations will help to identify and prevent diabetic keratopathy in a timely manner.


Assuntos
Córnea , Diabetes Mellitus Tipo 2 , Humanos , Hemoglobinas Glicadas , Fenômenos Biomecânicos , Pressão Intraocular , Elasticidade , Tonometria Ocular
12.
Int J Med Sci ; 21(5): 775-783, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38617013

RESUMO

Pulmonary surfactants, a complex assembly of phospholipids and surfactant proteins such as SP-B and SP-C, are critical for maintaining respiratory system functionality by lowering surface tension (ST) and preventing alveolar collapse. Our study introduced five synthetic SP-B peptides and one SP-C peptide, leading to the synthesis of CHAsurf candidates (CHAsurf-1 to CHAsurf-5) for evaluation. We utilized a modified Wilhelmy balance test to assess the surface tension properties of the surfactants, measuring spreading rate, surface adsorption, and ST-area diagrams to comprehensively evaluate their performance. Animal experiments were performed on New Zealand white rabbits to test the efficacy of CHAsurf-4B, a variant chosen for its economic viability and promising ST reduction properties, comparable to Curosurf®. The study confirmed that higher doses of SP-B in CHAsurf-4 are associated with improved ST reduction. However, due to cost constraints, CHAsurf-4B was selected for in vivo assessment. The animal model revealed that CHAsurf-4B could restore alveolar structure and improve lung elasticity, akin to Curosurf®. Our research highlights the significance of cysteine residues and disulfide bonds in the structural integrity and function of synthetic SP-B analogues, offering a foundation for future surfactant therapy in respiratory disorders. This study's findings support the potential of CHAsurf-4B as a therapeutic agent, meriting further investigation to solidify its role in clinical applications.


Assuntos
Surfactantes Pulmonares , Animais , Coelhos , Cisteína , Elasticidade , Surfactantes Pulmonares/farmacologia , Tensoativos
13.
PLoS One ; 19(3): e0291991, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38437234

RESUMO

INTRODUCTION: The sustainability of public hospital financing in Spain is a recurring issue, given its representativeness in annual public healthcare budgets which must adapt to the macroeconomic challenges that influence the evolution of spending. Knowing whether the responsiveness of hospital expenditure to its determinants (need, utilisation, and quasi-prices) varies according to the type of hospital could help better design strategies aimed at optimising performance. METHODS: Using SARIMAX models, we dynamically assess unique nationwide monthly activity data over a 14-year period from 274 acute-care hospitals in the Spanish National Health Service network, clustering these providers according to the average severity of the episodes treated. RESULTS: All groups showed seasonal patterns and increasing trends in the evolution of expenditure. The fourth quartile of hospitals, treating the most severe episodes and accounting for more than 50% of expenditure, is the most sensitive to quasi-price factors, particularly the number of beds per hospital. Meanwhile, the first quartile of hospitals, which treat the least severe episodes and account for 10% of expenditure, is most sensitive to quantity factors, for which expenditure showed an elasticity above one, while factors of production were not affected. CONCLUSIONS: Belonging to one or another cluster of hospitals means that the determinants of expenditure have a different impact and intensity. The system should focus on these differences in order to optimally modulate expenditure not only according to the needs of the population, but also according to the macroeconomic situation, while leaving hospitals room for manoeuvre in case of unforeseen events. The findings suggest strengthening a network of smaller hospitals (Group 1)-closer to their reference population, focused on managing and responding to chronicity and stabilising acute events-prior to transfer to tertiary hospitals (Group 4)-larger but appropriately sized, specialising in solving acute and complex health problems-when needed.


Assuntos
Gastos em Saúde , Medicina Estatal , Hospitais Públicos , Centros de Atenção Terciária , Elasticidade
14.
Sci Rep ; 14(1): 5623, 2024 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-38453994

RESUMO

Scoliosis is a three-dimensional spinal deformity, and paraspinal muscles play an important role as stabilizers of the spinal curve. In this prospective study, we compared elasticity changes in the paraspinal muscles of adolescent patients with scoliosis after surgery or bracing. Elasticity was measured on the concave and convex sides of the paraspinal muscles at the apex of the curve at the beginning of treatment and 6 and 12 months after treatment. Twenty-six patients with correction surgery (n = 15) or bracing (n = 11) were included. At initial evaluation, the Cobb angle was larger in the surgery group (72.3 ± 20.2° in surgery vs. 30.6 ± 5.1° in brace, p < 0.001). The estimated mean elasticity value of the paraspinal muscles was lower in the surgery group at baseline on the convex side (15.8 vs. 22.8 kPa, p = 0.037) and 6 months on both the concave (12.1 vs. 22.7 kPa, p = 0.004) and convex (13.4 vs. 23.8 kPa, p = 0.005) sides. There was a significant stiffness decrease from baseline to 6 months on the concave side in the surgery group (5.9 kPa, p = 0.025). However, the elasticity change recovered at 12 months without significant differences between the two groups.


Assuntos
Escoliose , Humanos , Adolescente , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Músculos Paraespinais/diagnóstico por imagem , Estudos Prospectivos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Elasticidade
15.
J Am Chem Soc ; 146(15): 10699-10707, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38518116

RESUMO

Ultralow temperature-tolerant electronic skins (e-skins) can endow polar robots with tactile feedback for exploring in extremely cold polar environments. However, it remains a challenge to develop e-skins that enable sensitive touch sensation and self-healing at ultralow temperatures. Herein, we describe the development of a sensitive robotic hand e-skin that can stretch, self-heal, and sense at temperatures as low as -78 °C. The elastomeric substrate of this e-skin is based on poly(dimethylsiloxane) supramolecular polymers and multistrength dynamic H-bonds, in particular with quadruple H-bonding motifs (UPy). The structure-performance relationship of the elastomer at ultralow temperatures is investigated. The results show that elastomers with side-chain UPy units exhibit higher stretchability (∼3257%) and self-healing efficiency compared to those with main-chain UPy units. This is attributed to the lower binding energy variation and lower potential well. Based on the elastomer with side-chain UPy and man-made electric ink, a sensitive robotic hand e-skin for usage at -78 °C is constructed to precisely sense the shape of objects and specific symbols, and its sensation can completely self-recover after being damaged. The findings of this study contribute to the concept of using robotic hands with e-skins in polar environments that make human involvement limited, dangerous, or impossible.


Assuntos
Elastômeros , Dispositivos Eletrônicos Vestíveis , Humanos , Elastômeros/química , Elasticidade , Pele , Eletricidade
16.
J Cosmet Dermatol ; 23(5): 1884-1890, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38444348

RESUMO

BACKGROUND: There is a growing trend of individuals wearing cosmetics while participating in physical activities. Nonetheless, there remains a need for further understanding regarding the effects of makeup on the facial epidermis during exercise, given the existing knowledge gaps. PURPOSE: This study aimed to evaluate the effects of a cosmetic foundation cream on skin conditions during physical activity. METHODS: Forty-three healthy college students, 20 males (26.3 ± 1.5 years) and 23 females (23.1 ± 1.0 years), were enrolled in this study. Foundation cream was applied to participants on half of the face in two different areas (MT: makeup T zone and MU: makeup U zone). The other half of the face served as internal control (T: non-makeup T zone and U: non-makeup U zones). Skin levels of moisture, elasticity, pore, sebum, and oil were measured using a skin analysis device (Aramhuvis, Gyeonggi, Republic of Korea) before and after a 20-min treadmill exercise. Paired t-test and independent t-test were performed for skin condition measurements at pre- and postexercise. RESULTS: The skin moisture levels in both the T and MT significantly increased after exercise (p < 0.05) (pre-T: 24.5 ± 1.3, post-T: 38.5 ± 3.5 and pre-MT: 18.7 ± 0.7, post-MT: 40.4 ± 4.8). Elasticity also significantly improved in both the T and MT (p < 0.05) (pre-T: 25.6 ± 1.3, post-T: 41.5 ± 3.5 and pre-MT: 20.0 ± 0.9, post-MT: 41.7 ± 3.7). The size of the pores in the T zone observed a significant increase after exercise (p < 0.05) (pre-T: 41.7 ± 2.1, post-T: 47.8 ± 2.4). The sebum levels in the T zone exhibited a reduction following physical activity, whereas there was a notable increase in sebum levels in the makeup zones (p < 0.05) (pre-MT: 2.4 ± 0.7, post-MT:4.2 ± 0.8 and pre MU 1.8 ± 0.34, post MU 4.9 ± 0.9). The oil level was increased in the non-makeup zones (pre-T: 6.1 ± 1.4, post-T: 11.8 ± 2.0 and pre-U: 7.3 ± 1.5, post-U: 11.9 ± 1.9; p < 0.05) and decreased in the makeup zones (pre-MT: 13.3 ± 1.9, post-MT: 7.4 ± 2.3 and pre-MU: 22.1 ± 2.4, post-MU: 3.2 ± 1.0; p < 0.05). CONCLUSIONS: The findings suggest that using foundation cream during aerobic exercise can reduce skin oil, causing dryness. Additionally, makeup can clog pores and increase sebum production. Therefore, wearing makeup may not be recommended for people with dry skin conditions based on the results of the current study. This research offers important insights to the public, encouraging them to consider the possible consequences of using makeup while exercising.


Assuntos
Exercício Físico , Creme para a Pele , Humanos , Feminino , Masculino , Adulto Jovem , Adulto , Exercício Físico/fisiologia , Creme para a Pele/administração & dosagem , Creme para a Pele/química , Sebo/metabolismo , Elasticidade/efeitos dos fármacos , Face , Cosméticos/administração & dosagem , Cosméticos/química , Teste de Esforço , Voluntários Saudáveis , Pele/efeitos dos fármacos , Pele/metabolismo , Pele/química , Epiderme/química , Epiderme/efeitos dos fármacos , Epiderme/fisiologia , Epiderme/metabolismo
17.
Eur Arch Otorhinolaryngol ; 281(5): 2609-2617, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38461420

RESUMO

PURPOSE: The aim of this prospective study was to investigate the diagnostic performance of shear wave elastography (SWE) in differentiating benign and malignant thyroid nodules and their correlation with the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS). METHODS: This prospective study included 370 thyroid nodules in 308 patients aged 18-70 years. All the patients underwent B-mode ultrasound (US), Doppler examination, and SWE and were given an ACR TI-RADS risk score before fine needle aspiration biopsy (FNAB) and/or surgery. The correlation between SWE parameters and ACR TI-RADS categories was investigated statistically and compared with histopathologic results. Additionally, the diagnostic performance of SWE was evaluated to distinguish malignant and benign thyroid nodules. RESULTS: One hundred and thirty-five of the 370 thyroid nodules were malignant, and 235 nodules were benign. The mean shear wave velocity (SWV) value of the malignant nodules (3.70 ± 0.98 m/s) was statistically higher than that of the benign nodules (2.70 ± 0.37 m/s). The best cutoff value of the mean SWV for differentiating benign and malignant nodules was found to be 2.94 m/s (sensitivity 90.4%, specificity 89.9%, positive predictive value 81.3%, negative predictive value 94.1%, p < 0.001). The average score of the nodules according to the ACR TI-RADS was 3.57 ± 1.83 in benign nodules and 7.38 ± 2.69 in malignant nodules (p ≤ 0.001). CONCLUSION: This study showed that combining SWE and TI-RADS improves the specificity of TI-RADS alone in differentiating benign and malignant nodules.


Assuntos
Técnicas de Imagem por Elasticidade , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Estudos Retrospectivos , Ultrassonografia/métodos , Elasticidade
18.
J Mol Graph Model ; 129: 108751, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38430695

RESUMO

In this paper, the finite element method is utilized to evaluate the behavior of the armchair phosphorene nanotubes under the compressive loading. The energy equations of the molecular and structural mechanics are used to obtain the elemental properties. The critical compressive forces of various armchair phosphorene nanotubes are computed with clamped-clamped and clamped-free boundary conditions. Results show that the stability of armchair phosphorene nanotubes increases with increasing nanotube aspect ratio, particularly under clamped-clamped boundary conditions. Finally, the buckling mode shapes of armchair phosphorene nanotubes under different boundary conditions are compared. Our work offers valuable insights into how these nanotubes respond to mechanical stress, helps determine elemental properties, and investigates the effects of nanotube geometry and different boundary conditions on their stability. This knowledge has broad applications in fields like nanotechnology, materials science, and nanomechanics, advancing the understanding of nanoscale materials and their potential for various practical uses.


Assuntos
Nanotubos , Análise de Elementos Finitos , Nanotubos/química , Nanotecnologia/métodos , Elasticidade
19.
Int J Biol Macromol ; 265(Pt 1): 130807, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484808

RESUMO

Magnetic superhydrophobic materials have broad application prospect in oil-water separation. In this study, a magnetic and superhydrophobic aerogel with lamellar structure was successfully prepared using cellulose nanofibrils (CNF) as the skeleton, Fe3O4 as the magnetic ion, 1H, 1H, 2H, 2H trialkylfluorooctane triethoxysilane (FS) and 3-(2-aminoethyl amino)-propyl trimethoxysilane (AS) as the combined modifier. The prepared aerogel shows lower density (38.63 mg/cm3), excellent magnetic (15.13 emu/g), high elasticity and good oil sorption properties (21 g/g). In addition, FS/AS also exhibits excellent mechanical properties and superhydrophobic ability (water contact angle (WCA) of 151.9 ± 1.4°), as it provides sufficient toughness and low surface energy for the layer-branch structure. It should be noted that the entire preparation process is carried out in the aqueous phase, without the use of any organic solvents, providing a green oil-water separation strategy.


Assuntos
Celulose , Água , Elasticidade , Compostos Radiofarmacêuticos , Interações Hidrofóbicas e Hidrofílicas
20.
J Mech Behav Biomed Mater ; 153: 106493, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38484428

RESUMO

Elastomeric biocomposites based on poly(glycerol adipate urethane) and hydroxyapatite were fabricated for tissue regeneration. The poly(glycerol adipate urethane) (PGAU) elastomeric composite matrices were obtained by chemical crosslinking of the poly(glycerol adipate) prepolymer (pPGA) with diisocyanate derivative of L-lysine. Two series of composites varying in the amount of L-lysine diisocyanate ethyl ester (LDI) used as a crosslinking agent were manufactured. As a ceramic filler both unmodified and L-lysine surface-modified hydroxyapatite (HAP) particles were used. The novelty of our research consists in the manufactured elastomeric materials and characterization of their linear viscoelastic (LVE) properties. The LVE properties of the composites were investigated by means of dynamic thermomechanical analysis. Frequency sweep and amplitude sweep measurements were performed in shear mode. The influence of the crosslinking agent (LDI) amount, HAP content and surface modification of HAP on the LVE properties of the composites was determined based on the analysis of the master curves of storage (G') and loss (G″) moduli and of tanδ of the composites. Depending on the amount of LDI, HAP and surface modification, the materials differ in the values of rubber elasticity plateau modulus (G0) and G' and G″ determined at selected shear frequencies and at the glassy state. G0 ranges from 278 kPa to 3.98 MPa, G' in the glassy state is within the range of 219 MPa-459 MPa. The G0 values of the PGAU-based composites are within the stiffness range of soft tissue. In view of the choice of HAP as the ceramic component and the G0 values, elastomeric composites have the potential to be used as filling materials in small bone defects (due to their mechanical similarity to osteoid) as well as materials for cartilage tissue regeneration.


Assuntos
Glicerol , Uretana , Glicerol/química , Lisina/química , Teste de Materiais , Elasticidade , Durapatita/química , Adipatos , Ésteres
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...